Rabu, 04 September 2019

Head AIR TERMINAL Smart ESE 98 Radius 120 Meter Spesialis Instalatir Penangkal Petir, Arrester Serta Pencegahan Bahaya Petir. Sedia Peralatan dan Suku Cadang Beserta Instalasi.



Produk / Jasa: AIR TERMINAL
Model: AIR TERMINAL
Negara Asal: CHINA
Merk: TSTLP

Anda akan mendapatkan :

Head Terminal Smart ESE 98 Radius 120 Meter
Connecting Sleeve
As Grounding 3/4 1 Meter
Kabel BC-50mm 15 Meter
Grounding (Pembumian) 12 Meter
Tiang Penyangga Galvanis 3 Meter
3 batang Pipa PVC 1/2
Bak kontrol 20x40mm
Accessories
Free Tes Grounding
Free Instalasi
GARANSI

HUBUNGI KAMI .

WA.085879862931

FAST RESPONSE : 085292554416

SURYATEHNIKPETIR@YAHOO.CO.ID


Detail Produk :
Brand name : TSTLP
MODEL Nr : SMART-ESE98 LEADER

Material : 304 stainless steel
Packing Detail : By 22.5X22.5X44.5 cm box/pc,4pcs in a big carton
Weight : 4.5 KGS
Volume weight after packing : 5 KGS

TECHNICAL SPEC
ese 98
PROTECTION RADIUS OF SMART ESE-98 LEADER
ese 981 ese 982
DIMENSION OF SMART ESE-98
ese 983
SMART ESE Lightning Conductor working principle
When lightning strikes, an electrical field is always created at ground level and this increases in
intensity as the downward leader approaches. Once this reaches a certain level between 50
and 100 kV/m the Corona effect, which develops naturally at the top of any high structure, allows
discharges known as upward leaders to rise toward the cloud (see previous section on the
lightning phenomenon).
The position of the ionised path which will allow the lightning current to pass is determined by where
the upward leader comes into contact with the first downward leader from the cloud.
The sooner the rising discharge (upward leader) leaves the lightning conductor to move toward the cloud, the sooner it will move closer.

Selasa, 03 September 2019

Penangkal Petir & grounding EROPA harga Lokal - Distributor Bakiral Semarang

               Mitra Technic Global

Spesialis Instalatir Penangkal Petir, Arrester Serta Pencegahan Bahaya Petir. Sedia Peralatan dan Suku Cadang Beserta Instalasi.









Anda mungkin pernah bermasalah dengan petir sehingga peralatan listrik di kantor atau pabrik anda menjadi rusak,untuk mengatasi itu, kami mempunyai solusi proteksi petir.
Bakiral ESE Air Terminal memenuhi standar NFC 17 102 dan sertifikasi ISO 8001-2008, ISO 14001-2004, OHSAS 18001-2007 dan CE Declaration of Confimity.
Semua Bakiral ESE Air Terminal dapat digunakan di semua industri seperti :
- Petrochemical, minyak dan gas
- Gedung Bertingkat tinggi dan Hotel
- Pertambangan
- Telekomunikasi dan broadcasting
- Sport Center (golf course, stadion)
- Penerbangan
- Fasilitas Industri
- Departemen Pertahanan Negara
- Power Generation dan distribusi
Kami menyediakan berbagai pilihan produk proteksi petir dari Bakiral.

LSP Streamer ( LEITAI Eksternal Lightning Protection )













LSP Streamer / LEITAI Eksternal Lightning Protection adalah penangkal petir jenis elektrosatic / early streamer emission. Merupakan penangkal petir jenis aktif yang dapat secara aktif dalam menjemput arus petir dan menyalurkan nya ke sistem pembumian / grounding system. Penangkal petir ini memiliki keunggulan yaitu radius proteksi yang lebih besar dan luas.
Penangkal petir LSP / LEITAI Lightning Protection ini dibuat dengan standarisasi NFC 17-102 dan UNE 21-186 yang populer digunakan dan diakui oleh negara – negara di Eropa.
Untuk penangkal petir LSP LEITAI ini tersedia dalam tipe LTDT-I  dengan spesifikasi radius proteksi = 85 meter, material full stainless steel
Penangkal petir LSP-LEITAI seri LTDT-I ini dilengkapi dengan adaptor dari bahan tembaga, sehingga mempermudah dalam pemasangannya dan telah disesuaikan dengan standarisasi pemasangan di Indonesia.
Terbuat dari bahan yang solid dan rigid sehingga lebih tahan terhadap sambaran petir, didukung dengan material full stainless steel sehingga membuat penangkal petir ini lebih tahan terhadap korosi dimana Indonesia merupakan iklim tropis dengan tingkat korosi yang sangat tinggi.

Jumat, 02 Agustus 2019

FITUR PRODUK PENANGKAL PETIR MAGELANG www.mediapetir.com KONVENSIONAL TEMANGGUNG ESE SISTEM SALATIGA SISTEM PENANGKA PETIR BOYOLALI PRODUK PENANGKAL PETIR DEMAK ANTIPETIR KUDUS GROUNDING PENANGKAL PETIR JEPARA SANGKAR FARADAY PEKALONGAN




 

HUBUNGI KAMI .

WA.0881 2944 392

FAST RESPONSE :081327187077

SURYATEHNIKPETIR@YAHOO.CO.ID










Ahlinya Penangkal Petir

Spesialis Instalatir Penangkal Petir, Arrester Serta Pencegahan Bahaya Petir. Sedia Peralatan dan Suku Cadang Beserta Instalasi.

Penangkal Petir dan Anti Petir mungkin itu adalah istilah yang sudah salah kaprah dalam bahasa kita, kesan yang ditimbulkan dua istilah ini adalah aman 100 % terhadap petir. Benarkah Demikian ?
Seringkali kita bernapas lega bila properti atau tempat kerja telah dipasang penangkal petir, baik yang terpasang sebagai pengaman sambaran langsung, atau pengaman tegangan kejutnya ( arrester ), dalam benak kita bahwa bahaya petir sudah tidak mungkin dapat merusak atau mencederai penghuni bangunan.
Peranggapan seperti ini tidaklah benar 100 % , masih ada kemungkinan terjadi kerusakan perangkat elektronik bila yang terjadi petir yang bertubi – tubi datangnya atau disebut juga dengan badai petir , sehingga sambaran petir berulangkali menyambar bangunan dalam tempo pendek.  Maka yang terjadi adalah perangkat elektronik yang ada akan hancur , dari hancurnya peralatan kita itulah maka dapat mencelakai seseorang Sesungguhnya apa yang terjadi ? kita akan bahan satu persatu .petir-berulang - penangkal petir

Peristiwa Sambaran Petir

Peristiwa sambaran petir yang mengenai sebuah bangunan ada dua macam :
1. Langsung mengenai bangunan.
2. Tidak langsung / disekitar bangunan .
Tentu tingkat kerusakan yang ditimbulkan tergantung dari ada tidaknya penangkal petir , bila ada, energi petir akan bisa di salurkan kedalam bumi dengan baik , bila tidak energi ini akan bisa menyalur sesuka hatinya . Bila yang dilalui perangkat elektronik akan hangus terbakar bila mengenai mahluk hudup akan mati hangus pula.
Langsung mengenai bangunan.
Dari seluruh energi petir yang disalurkan ke bumi masih ada sedikit energi yang kadangkala masuk di jaringan kabel daya ataupun data akibat peristiwa side flashing / petir keluar jalur penghantar , untuk menghilangkannya perlu dipasang pengaman tegangan surge ( kejut ) dengan memasang Arrester . Mulai dari Arrester listrik , arrester data , arrester antena .
Tidak langsung / disekitar bangunan .
Untuk sambaran tidak langsung kerusakan yang ditimbulkan adalah rambatan melalui jalur kabel yang masuk didalam bangunan , penanganannyapun juga melengkapi dengan Arrester .
Permisalan sambaran petir mengenai sisi atas bangunan yang sudah tersedia penangkal petir, akan tetapi terjadi kebocoran kabel penyalur petirnya ( side flashing ) yang rambatannya masuk di jaringan kabel kelistrikan . Karena arus petir ini besar diluar ambang batas Arrester akhirnya terjadi kerusakan Arrester .
Tidak seberapa lama kemudian terjadi sambaran petir diluar area bangunan , mengenai tiang listrik sejauh 100 mtr dari area , rambatan arus petir meniti jalur kabel mengarah di bangunan .
Sambaran pertama telah merusakkan perangkat arrester karena terlalu besar diluar ambang maksimal arrester . Maka sambaran petir kedua walau diluar area dan jauh akan bisa memporak porandakan perangkat elektronik didalam bangunan.
Kita ada pengalaman perihal serupa diatas , Client kami perusahaan layanan internet di salah satu towernya telah terjadi badai petir yang besar dan saat badai terjadi sempat swich off di panel kelistrikannya , keesokan harinya kami datang di lokasi untuk mengadakan pengecekan , tidak ada perangkat radio yang rusak , tetapi ada satu line arrester yang jebol terbakar. Kami informasikan perihal ini di bagian teknisi agar diadakan penggantian sesegera mungkin. Penggantian arrester direncanakan dalam dua hari kedepan , teryata sambaran ke dua tidak sabar menunggu dua hari alhasil sebuah perangkat radio ikut hangus di line yang kosong arresternya.
Sudahlah kita ketahui bahwa perangkat arrester memiliki kemampuan maksimal dalam memindahkan arus petir ke grounding dengan satuan Ampere yang biasa tertera dengan Imax : ….  Ampere. Kemampuan maksimal inilah bisa sebagai batasan dan kendala kemampuan teknologi saat ini.
Pengecekan Penangkal Petir dan System Arrester
Kerja ekstra dimusim penghujan haruslah di lakukan agar terhindar dari kerusakan . mulai dari mengecekan grounding dan tahanan tanah. pengecekan sistem pengkabelan ground dan pengecekan unit arrester.
Pengecekan Grounding Penangkal Petir dan Grounding listrik/arrester Acuan dasar ada di nilai tahan tanah Grounding yakni tidak boleh lebih dari 5 Ohm , bilamana lebih dari itu sebaiknya segera dilakukan penambahan unit grounding di sebelahnya dan di sambungkan / paralel dengan yang sudah ada.
Pengecekan jalur instalasi kabel Penyalur Petir, besar minimal dari kabel penghantar adalah 50 mm bila lebih besar akan lebih baik , penggunaan kabel kabel khusus penyalur petir semisal coaxial cable , xlpe kabel ( HVSC ) akan lebih baik dan mengurangi jalur berkelok kelok akan menghindari loncatan keluar lidah petir / side flashing .
Pengecekan Unit Arrester dan sistem grounding di panel dan pengkabelan, Unit arrester merupakan unit perangkat yang kompak jadi pengecekan sekilas saja sudah cukup yakni asal bentuk fisik masih utuh , tidak hangus. Bila ingin lebih teliti bisa dengan Ohm meter antar dua kaki arrester tidak terhubung. Pastikan si kaki graund arreseter benar benar terhubung ke grounding . Pastikan pula bahwa seluruh jalur kelistrikan sudah dilengkapi dengan jalur kabel grounding.
Setelah semuanya terpasang baik, barulah kita bisa bernapas lega sebab bahaya utama sambaran petir sudah di netralisir.

Baca Juga :

 



























  


























































Peran konduktor petir adalah untuk menangkap petir mengalir ke dalam tanah dengan bawah konduktor. duval Messien manufaktur dan menginstal petir konduktorTiga kategori.

Sederhana batang:Dengan tajam, poin, yang berasal dari sebelumnya desain. Mereka memberikan perlindungan untuk struktur kecil.

Early Streamer Emission (ESE):Perkembangan sederhana rod, tapi di mana efisiensi ditingkatkan dengan menggunakan perangkat yang dihasilkan menggunakan tegangan Tinggi untuk membuat efek korona. Hal ini mengurangi waktu pertemuan antara ke atas dan ke bawah pemimpin dan membuat desain cocok untuk jauh lebih besar struktur. duval Messien SATELIT rentang menggunakan komponen dari teknologi yang berbeda. Mereka memiliki kinerja tinggi dan kehandalan.

Meshed kandang atau ketat helai:Berdasarkan & laquo; kandang faraday & raquo;, terdiri jika perlu beberapa strike poin dipasang di seluruh bangunan dan menonjol Fitur secara berkala. Ini strike poin terhubung satu sama lain dengan jerat dilakukan dengan baik, konduktor dipasang di atap baik dengan kabel ditangguhkan di atas bangunan.
Cina Duval Messien ESE 6000 jenis Petir penangkal petir Batang Harga

Fitur Produk

Ini adalah jenis penangkal petir terbuat dari bahan stainless steel, memiliki berbagai perlindungan area
Dan berbagai fitur.

1.Tidak electron gaya hidup.
2.Menjaga kinerja yang baik setelah petir membelai.
3.Berbagai radius proteksi.
4.Tracing petir di muka dan konduksi ke Bumi sepenuhnya.
5.Ini akan diaktifkan hanya memiliki kilat dan guntur.
6.Artistik garis besar.
7.Aman dan dapat diandalkan.
8.Tanpa perawatan.


Gambar struktur
Cina Duval Messien ESE 6000 jenis Petir penangkal petir Batang Harga
Cina Duval Messien ESE 6000 jenis Petir penangkal petir Batang Harga


PERLINDUNGAN AREA (Duval Messien ESE Penangkal petir Arrester)

Nomor referensi.
T(AS)
LTDE 2500
25
LTDE 4500
45
LTDE 6000
60


(Duval Messien ESE Penangkal petir Arrester)
PERLINDUNGAN JARI-JARI RP (m)
Jenis SATELIT + G2
T = tinggi ESE tip (m)
2
4
5
7
10
15
20
45
60
Tingkat perlindungan 1
ESE 2500
17
34
42
43
44
45
45
45
45
ESE 4500
25
51
63
64
64
65
65
65
65
ESE 6000
32
64
79
79
79
80
80
80
80
Tingkat perlindungan 2
ESE 2500
23
45
57
59
61
63
65
70
70
ESE 4500
32
65
81
82
83
85
86
90
90
ESE 6000
40
75
97
98
99
101
102
105
105
Tingkat perlindungan 3
ESE 2500
26
52
65
66
69
72
75
84
85
ESE 4500
36
72
89
91
92
95
97
104
105
ESE 6000
44
87
107
108
109
111
113
120
120 

Aplikasi
Hal ini banyak digunakan untuk komunikasi nirkabel base station, mudah terbakar, ledakan barang gudang,
TinggiBangunan, Universitas, rumah sakit, sipil, kapal militer, bandara, bangunan bersejarah, balap kuda, olahraga dasar bahan kimia, karet, cat manufaktur, radar stasiun depot minyak, Meteorologi Stasiun gas stasiun pangkalan militer, tambang.

Cina Duval Messien ESE 6000 jenis Petir penangkal petir Batang Harga
Proyek
Sertifikasi
Kemasan & Pengiriman
Kemasan
Cina Duval Messien ESE 6000 jenis Petir penangkal petir Batang Harga


Cina Duval Messien ESE 6000 jenis Petir penangkal petir Batang Harga



penangkal petir kurn
No. Produk Penangkal Petir Radius & Aksesoris

HUBUNGI KAMI .

085879862931

FAST RESPONSE : 085292554416

SURYATEHNIKPETIR@YAHOO.CO.ID

 * KURN (Indonesia)Penangkal Petir KURN
penangkal petir kurn
  1.  Kurn R60-80           Call/WA Dapatkan Harga Termurah
  2.  Kurn R120-150      Call/WA Dapatkan Harga Termurah
  3.  Kurn Kurnia R85    Call/WA Dapatkan Harga Termurah
  4.  Kurn Kurnia R150  Call/WA Dapatkan Harga Termurah
Klik here download brosur penangkal petir KURN



 * EVO FRANKLIN EF (Lokal)
Penangkal Petir EVO FRANKLIN
penangkal petir evo franklin ef 60
  1. EVO FRANKLIN EF 60    Call/WA Dapatkan Harga Termurah
  2. EVO FRANKLIN EF 85    Call/WA Dapatkan Harga Termurah
  3. EVO FRANKLIN EF 150  Call/WA Dapatkan Harga Termurah
Klik here download brosur penangkal petir EVO FRANKLIN



 * PREVECTRON (Perancis)
Penangkal Petir PREVECTRON
penangkal petir prevectron
  1.  Prevectron R85    Call/WA Dapatkan Harga Termurah
  2.  Prevectron R100  Call/WA Dapatkan Harga Termurah
  3.  Prevectron R120  Call/WA Dapatkan Harga Termurah
Klik here download brosur penangkal petir PREVECTRON



 * VIKING (Indonesia)
Penangkal Petir VIKING
penangkal petir viking
  1.  Viking V3  Call/WA Dapatkan Harga Termurah
  2.  Viking V6  Call/WA Dapatkan Harga Termurah
Klik here download brosur penangkal petir VIKING



 * THOMAS (Indonesia)
Penangkal Petir THOMAS
penangkal petir thomas
  1.  Thomas R125  Call/WA Dapatkan Harga Termurah
  2.  Thomas R60    Call/WA Dapatkan Harga Termurah
  3.  Thomas R25    Call/WA Dapatkan Harga Termurah
Klik here download brosur penangkal petir THOMAS



 * FLASH VECTRON (Indonesia)
Penangkal Petir FLASH VECTRON
penangkal petir flash vectron
  1. Flash Vectron FV3 R85    Call/WA Dapatkan Harga Termurah
  2. Flash Vectron FV6 R150  Call/WA Dapatkan Harga Termurah
Klik here download brosur penangkal petir FLASH VECTRON



 * GENT (Indonesia)
Penangkal Petir GENT
penangkal petir flash gent
  1. Gent R150  Call/WA Dapatkan Harga Termurah
  2. Gent R75    Call/WA Dapatkan Harga Termurah
  3. Gent R35    Call/WA Dapatkan Harga Termurah
Klik here download brosur penangkal petir GENT



 * HELITA PULSAR (Perancis)
Penangkal Petir HELITA PULSAR
penangkal petir helita pulsar
  1. Helita Pulsar 18 R55    Call/WA Dapatkan Harga Termurah
  2. Helita Pulsar 30 R71    Call/WA Dapatkan Harga Termurah
  3. Helita Pulsar 45 R89    Call/WA Dapatkan Harga Termurah
  4. Helita Pulsar 60 R120  Call/WA Dapatkan Harga Termurah
Klik here download brosur penangkal petir HELITA PULSAR



 * LPI GUARDIAN (Australia)
Penangkal Petir LPI GUARDIAN
penangkal petir lpi guardian
  1. LPI Guardian Cat1 R77    Call/WA Dapatkan Harga Termurah
  2. LPI Guardian Cat2 R100  Call/WA Dapatkan Harga Termurah
  3. LPI Guardian Cat3 R110  Call/WA Dapatkan Harga Termurah
Klik here download brosur penangkal petir LPI GUARDIAN



 * Blue CRN2 ( Indonesia)
Penangkal Petir BLUE CRN2
penangkal petir blue crn2
  1. Blue CRN2 R120  Call/WA Dapatkan Harga Termurah
  2. Blue CRN2 R150  Call/WA Dapatkan Harga Termurah
  3. Blue CRN2 R80    Call/WA Dapatkan Harga Termurah
Klik here download brosur penangkal petir BLUE CRN2



 * EF (Swiss)
Penangkal Petir EF (Swiss)
penangkal petir ef
  1. EF (Swiss)  Call/WA Dapatkan Harga Termurah
Klik here download brosur penangkal petir EF (Swiss)



 * UFO (Indonesia)
Penangkal Petir UFO
penangkal petir ufo
  1. UFO F1 R70    Call/WA Dapatkan Harga Termurah
  2. UFO F2 R100  Call/WA Dapatkan Harga Termurah
Klik here download brosur penangkal petir UFO



 * NEO FLASH (Indonesia)
Penangkal Petir NEO FLASH
penangkal petir neoflash
  1. Neo Flash TZ03 R87    Call/WA Dapatkan Harga Termurah
  2. Neo Flash TZ04 R100  Call/WA Dapatkan Harga Termurah
  3. Neo Flash TZ05 R125  Call/WA Dapatkan Harga Termurah
  4. Neo Flash TZ06 R150  Call/WA Dapatkan Harga Termurah
Klik here download brosur penangkal petir NEO FLASH



 * CPT Nimbus (Spanyol)
Penangkal Petir CPT Nimbus
penangkal petir lpi stomaster ese50
  1. CPT Nimbus 15  Call/WA Dapatkan Harga Termurah
  2. CPT Nimbus 30  Call/WA Dapatkan Harga Termurah
  3. CPT Nimbus 45  Call/WA Dapatkan Harga Termurah
  4. CPT Nimbus 60  Call/WA Dapatkan Harga Termurah
Klik here download brosur penangkal petir CPT Nimbus



 * Zeus (Indonesia)
Penangkal Petir ZEUS
penangkal petir zeus
  1. CPT Zeus R150 (Bulat)                      Call/WA Dapatkan Harga Termurah
  2. CPT Zeus Konvensional (Panjang)  Call/WA Dapatkan Harga Termurah
Klik here download brosur penangkal petir ZEUS



 * Orion (Indonesia)
Penangkal Petir ORION
penangkal petir orion
  1. Orion  Call/WA Dapatkan Harga Termurah
Klik here download brosur penangkal petir ORION



 * Erico (USA)
Penangkal Petir ERICO
penangkal petir erico
  1. Erico System 3000 R120  Call/WA Dapatkan Harga Termurah
Klik here download brosur penangkal petir ERICO



 * CURRENT (Indonesia)
Penangkal Petir CURRENT
penangkal petir current
  1. Current Type "C" R70    Call/WA Dapatkan Harga Termurah
  2. Current Type "C" R120  Call/WA Dapatkan Harga Termurah
Klik here download brosur penangkal petir CURRENT



 * BAKIRAL (Turki)
Penangkal Petir BAKIRAL
penangkal petir bakiral
  1. Bakiral  Call/WA Dapatkan Harga Termurah
Klik here download brosur penangkal petir BAKIRAL



 * LPI STORMASTER ESE50 (Lokal)
Penangkal LPI STORMASTER ESE50
penangkal petir lpi stomaster ese50
  1. LPI Stormaster ESE50  Call/WA Dapatkan Harga Termurah
Klik here download brosur penangkal petir LPI STORMASTER ESE50



 * Luxor (Indonesia)
Penangkal Petir LUXOR
penangkal petir luxor
  1. Luxor R20  Call/WA Dapatkan Harga Termurah
  2. Luxor R70  Call/WA Dapatkan Harga Termurah
  3. Luxor R100  Call/WA Dapatkan Harga Termurah
Klik here download brosur penangkal petir LUXOR



 * Penangkal Petir Konvensional
Splitzen Tombak Penangkal Petir
penangkal petir evo franklin ef 60
  1. Splitzen Full Tembaga 3/4" 50cm  Call/WA Dapatkan Harga Termurah
  2. Splitzen Full Tembaga 3/4" 30cm  Call/WA Dapatkan Harga Termurah
  3. Splitzen Full Tembaga 5/8" 50cm  Call/WA Dapatkan Harga Termurah
  4. Splitzen Full Tembaga Trisula  Call/WA Dapatkan Harga Termurah
  5. Splitzen Babet 3/4" 60cm  Call/WA Dapatkan Harga Termurah
  6. Splitzen 1 Set (spit, teflon, tiang 3/4" 60cm)  Call/WA Dapatkan Harga Termurah
  7. Splitzen 1 Set (spit, teflon, tiang 5/8" 60cm)  Call/WA Dapatkan Harga Termurah


 * Kabel BC
Kabel BC Penangkal Petir
penangkal petir evo franklin ef 60
  1. Kabel BC 35mm  Call/WA Dapatkan Harga Termurah
  2. Kabel BC 50mm  Call/WA Dapatkan Harga Termurah
  3. Kabel BC 70mm  Call/WA Dapatkan Harga Termurah
  4. Kabel BC 120mm  Call/WA Dapatkan Harga Termurah
  5. Kabel BC 150mm  Call/WA Dapatkan Harga Termurah
  6. Kabel BC 240mm  Call/WA Dapatkan Harga Termurah
  7. KABEL GROUNDING ( KABEL BC ) 4mm  Call/WA Dapatkan Harga Termurah
  8. KABEL GROUNDING ( KABEL BC ) 6mm  Call/WA Dapatkan Harga Termurah
  9. KABEL GROUNDING ( KABEL BC ) 10mm  Call/WA Dapatkan Harga Termurah
  10. KABEL GROUNDING ( KABEL BC ) 16mm  Call/WA Dapatkan Harga Termurah
  11. KABEL GROUNDING ( KABEL BC ) 25mm  Call/WA Dapatkan Harga Termurah
  12. KABEL GROUNDING ( KABEL BC ) 35mm  Call/WA Dapatkan Harga Termurah
  13. KABEL GROUNDING ( KABEL BC ) 50mm  Call/WA Dapatkan Harga Termurah
  14. KABEL GROUNDING ( KABEL BC ) 70mm  Call/WA Dapatkan Harga Termurah
  15. KABEL GROUNDING ( KABEL BC ) 95mm  Call/WA Dapatkan Harga Termurah
  16. KABEL GROUNDING ( KABEL BC ) 120mm  Call/WA Dapatkan Harga Termurah
  17. KABEL GROUNDING ( KABEL BC ) 150mm  Call/WA Dapatkan Harga Termurah
  18. KABEL GROUNDING ( KABEL BC ) 185mm  Call/WA Dapatkan Harga Termurah
  19. KABEL GROUNDING ( KABEL BC ) 240mm  Call/WA Dapatkan Harga Termurah


 * Kabel NYA
Kabel NYA Penangkal Petir
penangkal petir evo franklin ef 60
  1. Kabel NYA 35mm  Call/WA Dapatkan Harga Termurah
  2. Kabel NYA 50mm  Call/WA Dapatkan Harga Termurah
  3. Kabel NYA 70mm  Call/WA Dapatkan Harga Termurah


 * Kabel Coaxial Penangkal Petir
Kabel Coaxial Penangkal Petir Liteco
penangkal petir evo franklin ef 60
  1. Kabel Coaxial 2x35mm  Call/WA Dapatkan Harga Termurah
  2. Kabel Coaxial 1x50mm  Call/WA Dapatkan Harga Termurah
  3. Kabel Coaxial 1x70mm  Call/WA Dapatkan Harga Termurah


 * Kabel NYY
Kabel NYY Penangkal Petir
penangkal petir evo franklin ef 60
  1. Kabel NYY 50mm  Call/WA Dapatkan Harga Termurah
  2. Kabel NYY 70mm  Call/WA Dapatkan Harga Termurah
  3. Kabel NYY 120mm  Call/WA Dapatkan Harga Termurah
  4. Kabel NYY 2x1,5mm  Call/WA Dapatkan Harga Termurah


 * Kabel NYM
Kabel NYM Penangkal Petir
penangkal petir evo franklin ef 60
  1. Kabel NYM 3x1,5mm  Call/WA Dapatkan Harga Termurah
  2. Kabel NYM 3x2,5mm  Call/WA Dapatkan Harga Termurah
  3. Kabel NYM 2x1,5mm  Call/WA Dapatkan Harga Termurah
  4. Kabel NYM 2x2,5mm  Call/WA Dapatkan Harga Termurah
  5. Kabel NYM 3x4mm  Call/WA Dapatkan Harga Termurah
  6. Kabel NYM 4x2,5mm  Call/WA Dapatkan Harga Termurah
  7. Kabel NYM 4x4mm  Call/WA Dapatkan Harga Termurah
  8. Kabel NYM 4x6mm  Call/WA Dapatkan Harga Termurah
  9. Kabel NYM 4x10mm  Call/WA Dapatkan Harga Termurah


 * Kabel A3CS
Kabel A3CS Penangkal Petir
penangkal petir evo franklin ef 60
  1. Kabel NYA 35mm  Call/WA Dapatkan Harga Termurah
  2. Kabel NYA 50mm  Call/WA Dapatkan Harga Termurah
  3. Kabel NYA 70mm  Call/WA Dapatkan Harga Termurah


 * Aksesoris Penangkal Petir
Aksesoris Penangkal Petir
penangkal petir evo franklin ef 60
  1. Ground Rod Diameter 16mm  Call/WA Dapatkan Harga Termurah
  2. Clamp Grounding  Call/WA Dapatkan Harga Termurah
  3. Clamp Cincin  Call/WA Dapatkan Harga Termurah
  4. Earthing Copper  Call/WA Dapatkan Harga Termurah
  5. Sock 5/8"  Call/WA Dapatkan Harga Termurah


 * Lampu Tower Penangkal Petir
Lampu Tower PHILIPS
penangkal petir evo franklin ef 60
  1. Lampu Tower XGP500  Call/WA Dapatkan Harga Termurah
  2. Lampu Tower XGP388  Call/WA Dapatkan Harga Termurah.

Penangkal Petir untuk Rumah dengan Sistem Konvensional

Ditulis oleh Administrator3 pada Minggu, 07 Oktober 2018 | Dilihat 2611 kali
Penangkal Petir untuk Rumah dengan Sistem Konvensional

Apa itu Petir

Petir adalah kilatan cahaya hasil dari pertemuan awan bermuatan positif dengan awan bermuatan negatif. Kilatan cahaya ini akan menyambar benda yang tertinggi.
Benda tertinggi bisa jadi hotel bertingkat, menara rumah tingkat dan lain-lain.
Pada artikel pembahasan kali ini kita merucut pada rumah saja.
Tentu yang awam akan bertanya-tanya metode seperti apa yang sebaiknya dipergunakan untuk memasang instalasi penangkal petir tersebut?
Adakah ketentuan nilai hambatan-hambatan tertentu yang menjadi ambang batas?

JENIS PENANGKAL PETIR

Di tinjau dari jenis penangkal petir terdapat 2 (dua) jenis penangkal petir, yaitu:
  • Penangkal petir konvensional
  • Penangkal petir radius
Pada kesempatan kali ini kita hanya membahas penangkal petir konvensional karena jenis penangkal petir ini yng sering di gunakan.
Daripada berlama-lama pembukaan, yuk kita ulas bersama di bawah ini.
Baca juga:

KONSTRUKSI PENANGAL PETIR KONVENSIONAL DI LUAR RUMAH

Bagaimana dengan instalasi grounding di bagian luar atau outdoor. Untuk tipe yang umum atau konvensional bisa dilihat pada gambar berikut :
Contoh Instalasi Grounding Rumah
Gambar. Contoh Instalasi Grounding Rumah
Dari gambar dapat dijelaskan sebagai berikut :
1. Sistem grounding yang terpasang ada dua macam yaitu untuk instalasi listrik rumah dan instalasi penangkal petir. Dua system grounding ini memang harus dipisahkan pemasangannya dan berjarak paling tidak 10 m.
2. Koneksi grounding untuk instalasi listrik rumah terpasang di kWh meter PLN.
Baca juga:

KOMPONEN INSTALASI GROUNDING

Komponen instalasi grounding adalah sebagai berikut :
1. Grounding rod, yaitu batang grounding yang ditanam di dalam tanah. Terdiri dari pipa galvanis medium , kawat tembaga BC berdiamater 16 mm2, Dan dilengkapi dengan splitzen yang dikencangkan dengan baut. Panjang grounding rod ini biasanya antara 1.5 m s/d 3 m.
2. Pipa PVC, yang digunakan sebagai selubung (konduit) dari kabel grounding yang ditanam dalam dinding / tembok atau untuk jalur kabel penangkal petir.
Dari kWh meter, kawat tembaga BC yang terpasang dalam pipa PVC sebagai konduit bertemu dengan grounding rod dalam satu bak kontrol.
Untuk instalasi penangkal petir, air terminal yang terpasang harus mampu meng-coversampai radius 120 derajat.
Dan di posisi air teminal, batang tembaga disambung dengan kabel BC langsung menuju grounding rod.
Detail dari masing-masing instalasi adalah sebagai berikut :
Detail Komponen Grounding Rod
Gambar. Detail Komponen Grounding Rod
Detail Komponen Air Terminal dari Penangkal Petir
Gambar. Detail Komponen Air Terminal dari Penangkal Petir
Baca juga:

PARAMETER DALAM MENENTUKAN KUALITAS GROUNDING

Parameter yang paling penting dalam menilai kualitas grounding adalah resistansi atau nilai tahanan dalam satuan Ohm, yang terukur di koneksi grounding tersebut.
Semakin kecil nilai tahanannya, semakin baik grounding tersebut. Artinya arus gangguan listrik atau petir dapat lebih cepat menuju bumi tanpa hambatan berarti.
Ingatlah, arus listrik secara alami cenderung mencari jalan dengan hambatan termudah...(prinsipnya sama dengan manusia yah..)
Nilai yang umum dipakai adalah nilai tahanan maksimal 5 Ohm untuk instalasi listrik rumah dan maksimal 2 ohm untuk instalasi petir. Hal ini juga sesuai dengan yang dinyatakan dalam PUIL 2011.

Berapa Panjang Batang Grounding yang Harus Terpasang?

Yang perlu dicatat disini adalah, nilai tahanan yang didapat tidak selalu sama dengan panjang grounding rod yang terpasang, karena sangat tergantung pada kondisi tanah dimana instalasi grounding ini dipasang.
Bila kondisi tanahnya mempunyai nilai tahanan rendah, maka cukup dipasang satu atau dua batang grounding rod dan tahanan yang terukur dapat mencapai dibawah 5 Ohm.
Bila tahanan terukur masih tinggi, maka panjang grounding rod harus ditambah agar lebih dalam lagi.
Bila pada kedalaman tertentu nilai tahanan masih tinggi, maka sebaiknya pindahkan posisi grounding rod tersebut.
Mengacu pada PUIL 2011 menjelaskan, jika daerah yang mempunyai jenis tanah yang nilai tahanannya tinggi, tahanan grounding-nya boleh mencapai maksimal 10 Ohm.

Earth Tester

Pengukuran nilai tahanan ini menggunakan earth tester, dimana alat ukur ini sudah menjadi alat wajib bagi kontraktor yang mengerjakan instalasi grounding. Anda hanya perlu memastikan bahwa nilai tahanan yang terukur sudah sesuai dengan persyaratan instalasi grounding.
Jadi bukan berapa meter grounding rod ditanam, tapi nilai resistansi yang harus jadi parameter utama.